Calculators & Converters

Convert binary to hex. Turn milliamps into pressure. Find the counts that move a machine. Enter your values and follow the calculation.

Runs in your browser · No account needed

Read hex four bits at a time.

Start at the right. Split the binary number into groups of four, then replace each group with its hex digit.

1010A10
1100C12
AC₁₆ = 10 × 16 + 12 = 172₁₀

4 bits = 1 nibble = 1 hex digit. Two nibbles make one byte. That is why a byte always fits in two hex digits.

Open the binary / hex cheat sheet

Browse all calculators

12 calculators · 12 cheat sheets · 3 worked jobs
Binary, Decimal & Hex ConverterConvert binary, decimal, hexadecimal and octal. Flip bits, inspect nibbles and compare signed integers through 64 bits.Binary to hex / Hex to decimalBits & Bytes Converter / Transfer TimeConvert bits, bytes, MB and MiB, then estimate ideal transfer time from a link rate in megabits per second.Bytes to bits / MiB to MBIEEE 754 Float & Modbus Register ConverterDecode IEEE-754 float32 bytes or encode a REAL value. Compare four byte orders, two register values and the underlying bits.Decode REAL 1.0 / Swapped words: CDABUnit Converter: Length, Pressure & MoreConvert length, pressure, temperature, flow, torque and other engineering units with explicit dimensions and conversion factors.cm to inches / bar to psi4–20 mA & Analog Scaling CalculatorScale 4–20 mA, voltage or raw PLC counts into engineering units. Reverse the calculation and inspect unclamped overrange.4–20 mA to 0–10 bar / 0–10 V to 0–100%4–20 mA Loop Voltage CalculatorCheck a two-wire current loop’s supply, transmitter requirement, receiver burden and cable resistance at the chosen current.24 V supply, 20 mA / Supply too lowModbus Register Address ConverterTranslate zero-based offsets, one-based indexes and conventional 5- or 6-digit Modbus references without off-by-one errors.40001 to wire offset / Register 40101Modbus RTU CRC Calculator & CheckerAppend or verify CRC-16/MODBUS from hexadecimal bytes. See the expected low-byte-first trailer and corrected frame.Calculate a request CRC / Verify a correct frameIPv4 Subnet CalculatorFind the mask, network, broadcast and host range for an IPv4 CIDR address. Check a PLC or HMI peer against that subnet.PLC and HMI on /27 / Same first octets, wrong subnetEncoder Resolution CalculatorConvert encoder pulses and quadrature decoding into counts, travel resolution and frequency at the counter input.1,000 PPR with x4 decoding / Compare x1 decodingGear Ratio & Conveyor Speed CalculatorCalculate output RPM and belt speed from motor speed, an input-to-output gear ratio and roller diameter.30:1 gearbox, 100 mm roller / Double the roller diameterPLC Scan Time & Pulse CalculatorExplore whether a cyclic PLC task samples a pulse and whether a non-retentive on-delay timer reaches its preset.A pulse the PLC misses / Same pulse, different phase